Статті КТППтаПМ УДХТУ
Permanent URI for this collectionhttps://crust.ust.edu.ua/handle/123456789/20500
ENG: Articles
Browse
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Assessment of the Efficiency of Hot Helium Tank Pressurization Systems for Oxygen-Propelled Rocket Engines(Publishing House “Akademperiodyka”, Kyiv, 2025) Sukhyi, Kostiantyn M.; Voit, S. M.; Mitikov, Yurii O.; Spirkin, S. V.; Sukha, Iryna V.ENG: For the first time, a study of the design has been conducted, and a detailed weight summary of the hot helium pressurization system for an oxidizer tank of the first stage of a launch vehicle (LV) has been presented; the propulsion system of this LV uses boiling oxygen — RG-1 as propellants. The oxidizing generator gas was considered as the heat exchanger heat carrier. The weight of this system was also evaluated for an alternative common heat carrier — reduced generator gas. A good correlation was shown between the obtained results and known data from other pressurization systems. The efficiency of hot helium pressurization systems is demonstrated in the case of multiple reuses of the first stage of an LV. It is also reasonable to use it for the dual activation of the liquid rocket engine (LRE) of the second stage of an LV. In these cases, arising issues are solved using well-established, proven solutions. However, an analysis of technical literature shows that alternative solutions have not been thoroughly studied. In other cases, considering the high cost, structural complexity, actual low reliability, and lack of weight advantages, the use of hot helium pressurization systems (PS) is hardly justified. This primarily concerns LREs with afterburning of generator gas, where oxidizing gas is used as the coolant in the heat exchanger. It is also noted that it is necessary to provide helium reserves on board of the LV and to introduce a gas pressure regulation system in the tank. This is due to the large variations in pressurization path resistance and helium temperatures after the heat exchanger at the design stage. The result is an increase in the calculated gas pressure in the tank, leading to an additional weight increase of 5–8%. It is shown that helium reserves can be easily adjusted based on the results of the first flight tests, whereas reducing the thickness of the tank walls and the diameter of the hot pressurization pipelines with thermal compensators is extremely problematic.Item type:Item, Bioactive Coatings on Ti–Zr–Nb Alloy: Synthesis, Characterization and Implantology Potential(MDPI AG, Basel, Switzerland, 2026) Kovalenko, Kseniia; Sukhyi, Kostiantyn M.; Fedak, Marcel; Rimar, Miroslav; Kalinichenko, Oleh O.; Yeromin, Oleksandr O.; Shmychkova, Olesia B.; Kulikov, Andrii; Kovalyov, Stanislav V.; Sukhyi, MykhailoENG: This research reports on the properties of oxide-ceramic coatings produced by plasma electrolytic oxidation in novel electrolyte solutions for implantology applications. A series of bioactive calcium-phosphate coatings was synthesized on medical-grade Ti-13Zr-13Nb alloy using the plasma electrolytic oxidation (PEO) method. Novel electrolytes enriched with calcium and phosphorus were developed, enabling the formation of coatings with tailored physicochemical and structural characteristics. A correlation was established between the electrolyte composition and the phase composition, thickness, morphology, porosity, and microhardness of the resulting coatings. The optimum coatings exhibited a Ca/P ratio close to that of natural human bone tissue, homogeneity, a well-developed porous surface topography, and controlled resorption behavior. For the first time, a mechanism of calcium-phosphate coating resorption in a biologically active environment has been proposed. It involves partial dissolution, the formation of apatite-like surface structures, and the subsequent controlled release of Ca and P ions. In vitro testing in simulated body fluid indicated the potential bioactivity of the synthesized coatings. The proposed calcium-phosphate coatings may be considered promising candidates for future implant surface modification. The results obtained are significant for the development of advanced orthopedic and dental implants, including those fabricated using additive manufacturing technologies.